{"product_id":"ups_power_pdus_server-technology_c2xg36te-dqme2966_c","title":"Server Technology PRO2 Expansion PDU","description":"Server Technology C2XG36TE-DQME2966\/C Switched POPS Expansion Pro2 PDU - 36x Configurable Alt Phase HDOT Outlets - 208v - 3-phase - 60a\u003cbr\u003e\u003cbr\u003eThe Server Technology PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack\/cabinet. The integral PIPS and POPS technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS Primary PDU can be connected to as many as three (with optional module) PRO2 Switched POPS Link PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.\u003cp\u003e\u003c\/p\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eModel Number\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003ePRO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eServer Technology PRO2 Expansion PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003ePDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eHDOT Cx Outlets\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eCx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eHot-Swap Network Card\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eNetwork access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eTemperature\/Humidity Monitoring\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eSupports two external 10'' (3m) T\/H probes. Receive SNMP-based alerts and email notifications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eAuto-Flip Current Display\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eEasy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high density cabinets.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003ePer-Outlet Power Sensing\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003ePOPS (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eBranch Circuit Protection\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eUL 489, CSA C22.2 No. 5 \u0026amp; IEC\/EN60947-2 Compliant 2-pole, 20A trip circuit breakers, six (6) branch, rating:  16A, 10 kAIC Interrupt Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eAlternating-Phase Outlets\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eEvenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eHigh Temperature Rating\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eThis product has been tested and approved for safe and reliable operation in 60 C data center environments.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eColor-Coded Options\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eSelect from six colors to designate PDU circuits in the data center  black, white, red, green, blue, and yellow.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eNetwork Monitoring\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eStar Multi-Linking\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003ePRO2 provides the ability to link up to four power circuits using one IP address.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eIP Access, Security \u0026amp; Communications\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eWeb, SSH, Telnet, SNMPv2c \u0026amp; v3, RS-232 serial, 10\/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, \u0026amp; SMTP\/email.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003ePer-Inlet Power Sensing\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003ePIPS (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, \u0026amp; Energy per inlet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eBranch Current Monitoring\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eMonitors current at each breaker branch and provides SNMP based alerts and emails on high usage that risks a tripped circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eOutlet Control\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eOn Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eHigh Retention Locking Outlets\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003ePRO2 receptacles have high retention and are compatible with P-Lock type power cords.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eFlexible Mounting\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eIncludes standard button mounts along with provisions for custom mounting brackets.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eInput Voltage (V)\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eFrequency\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eInput Plug\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e208V Delta 60A IEC 60309 3P+G 9Hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eInput Current (A)\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eInput Current Rated (A)\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eInput Power Capacity (kW)\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e17.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eConnector\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eRating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e(24) x IEC 60320\/C13 North American Rating\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e12A @208V L-L (15A Peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e(12) x Cx North American Rating\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e16A @208V L-L (20A Peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003ePhysical\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eDimensions: 70.0in tall x 2.2in wide x 2.5in deep [1778mm x 56mm x 64mm]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eEnvironmental\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eOperating Environment: 32F to 140F \/ 0C to 60C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eCommunications \u0026amp; Security\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e10\/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eCertifications\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eNorth American:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eInput Measurement Accuracy:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eOutput Measurement Accuracy\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eGUI Current =  1% at 0.01 amp resolution (above 0.15 amp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003eBranch Measurement Accuracy\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003eCurrent =  3% at 0.01 amp resolution (above 0.5 amp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Server Technology","offers":[{"title":"New","offer_id":45018183991432,"sku":"C2XG36TE-DQME2966\/C_C1","price":613.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/7020\/8392\/files\/a5a8a439-2ae5-4a80-9a7f-60636b39fd99.jpg?v=1780559506","url":"https:\/\/www.techforless.com\/products\/ups_power_pdus_server-technology_c2xg36te-dqme2966_c","provider":"Tech For Less","version":"1.0","type":"link"}