Server Technology PRO2 Primary PDU
Hurry up, only 3 items left in stock.
Couldn't load pickup availability
Offering New, Open Box & Refurbs at 10-50% Off Retail
Helping you save money since 2001
Product Condition
Product Condition
Product Details
Product Details
The Server Technology PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS and POPS technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS Primary PDU can be connected to as many as three (with optional module) PRO2 Switched POPS Link PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
| Model Number | PRO2 |
| Product Name | Server Technology PRO2 Primary PDU |
| Product Type | PDU |
| HDOT Cx Outlets | Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs. |
| Hot-Swap Network Card | Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit. |
| Temperature/Humidity Monitoring | Supports two external 10'' (3m) T/H probes. Receive SNMP-based alerts and email notifications. |
| Auto-Flip Current Display | Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high density cabinets. |
| Per-Outlet Power Sensing | POPS (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet. |
| Branch Circuit Protection | UL 489, CSA C22.2 No. 5 & IEC/EN60947-2 Compliant 2-pole, 20A trip circuit breakers, six (6) branch, rating: 16A, 10 kAIC Interrupt Rating |
| Alternating-Phase Outlets | Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow. |
| High Temperature Rating | This product has been tested and approved for safe and reliable operation in 60 C data center environments. |
| Color-Coded Options | Select from six colors to designate PDU circuits in the data center black, white, red, green, blue, and yellow. |
| Network Monitoring | Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more. |
| Star Multi-Linking | PRO2 provides the ability to link up to four power circuits using one IP address. Primary Expansion PDU provides backup power to network card. |
| IP Access, Security & Communications | Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email. |
| Per-Inlet Power Sensing | PIPS (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet. |
| Branch Current Monitoring | Monitors current at each breaker branch and provides SNMP based alerts and emails on high usage that risks a tripped circuit. |
| Outlet Control | On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles. |
| High Retention Locking Outlets | PRO2 receptacles have high retention and are compatible with P-Lock type power cords. |
| Flexible Mounting | Includes standard button mounts along with provisions for custom mounting brackets. |
| Input Voltage (V) | 208 |
| Frequency | 50/60 Hz |
| Input Plug | 208V Delta 60A IEC 60309 3P+G 9Hr |
| Input Current (A) | 60 |
| Input Current Rated (A) | 48 |
| Input Power Capacity (kW) | 17.3 |
| Connector | Rating |
| (24) x IEC 60320/C13 North American Rating | 12A @208V L-L (15A Peak) |
| (12) x Cx North American Rating | 16A @208V L-L (20A Peak) |
| Physical | Dimensions: 70.0in tall x 2.2in wide x 2.5in deep [1778mm x 56mm x 64mm] |
| Environmental | Operating Environment: 32F to 140F / 0C to 60C |
| Communications & Security | 10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector) |
| Certifications | North American: |
| Measurement Accuracy | Input Measurement Accuracy: |
| Output Measurement Accuracy | GUI Current = 1% at 0.01 amp resolution (above 0.15 amp) |
| Branch Measurement Accuracy | Current = 3% at 0.01 amp resolution (above 0.5 amp) |